Introduction

Bimonthly, started in 1957
Administrator
Shanxi Provincial Education Department
Sponsor
Taiyuan University of Technology
Publisher
Ed. Office of Journal of TYUT
Editor-in-Chief
SUN Hongbin
ISSN: 1007-9432
CN: 14-1220/N
location: home > paper >
References:
  • PDFdownloadsize:3.25MBviewed:download:
  • Color Discrimination Ability of Normal Observers under Standard Illuminants with Different Correlated Color Temperatures
    DOI:
    10.16355/j.cnki.issn1007-9432tyut.2022.05.017
    Received:
    Accepted:
    abstract:

    The effect of illuminants with different correlated color temperatures on color discrimination ability was investigated by asking 20 color normal observers to perform FM-100 test under D65, TL84, and F illuminants. The experimental results show that the TESs (Total Error Scores) under D65 and TL84 were not significantly different between them, but they were significantly lower than the TES under F illuminant; for F illuminant, the PES (Partial Error Score) along blue-yellow axis was much higher than that along red-green axis. The results indicate that in FM-100 test F illuminant cannot be used as a lighting source, because the color discrimination ability, in particular blue-yellow color discrimination ability, is much reduced under this illuminant.


    Keywords:
    color temperature; standard illuminant; FM-100 test; color normal observers